@ -1,6 +1,11 @@
				@@ -1,6 +1,11 @@
					 
			
		
	
		
			
				
					//Useful Websites
  
			
		
	
		
			
				
					//http://math.stackexchange.com/questions/406082/numerical-method-to-solve-a-trigonometric-cotangent-function-transient-heat
  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					//Global Variables for Turkey
  
			
		
	
		
			
				
					density  =  996 ;  // kg/m3 Assuming Density of Water 1000 kg/m3
  
			
		
	
		
			
				
					cp  =  2810  // J/kg K for Turkey
  
			
		
	
		
			
				
					heatConvection  =  12 ;  // W/m2 K Some Reasonable estimate for natural Convection. Change as needed. 5-25
  
			
		
	
		
			
				
					thermalConduct  =  0.412  // W/m K
  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  celsiusToFarenheit ( celsius )  {  
			
		
	
		
			
				
					farenheit  =  ( celsius * ( 9 / 5 ) )  +  32 ;  
			
		
	
	
		
			
				
					
						
							
								 
						
						
							
								 
						
						
					 
				
				@ -51,13 +56,10 @@ console.log("Simple Radius  " + simpleRadius + " Meters")
				@@ -51,13 +56,10 @@ console.log("Simple Radius  " + simpleRadius + " Meters")
					 
			
		
	
		
			
				
					console . log ( "Complex Radius  "  +  complexRadius  +  " Meters" )  
			
		
	
		
			
				
					}  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  L umpedCapacitanceMethod( radiusTotal , radiusInner , tempInitial , tempInfini ,  t )  {  
			
		
	
		
			
				
					function  l umpedCapacitanceMethod( radiusTotal , radiusInner , tempInitial , tempInfini ,  t )  {  
			
		
	
		
			
				
					name  :  "Skin"  
			
		
	
		
			
				
					volume  =  ( 4 / 3 ) * Math . PI * Math . pow ( radiusTotal , 3 )  -  ( 4 / 3 ) * Math . PI * Math . pow ( radiusInner , 3 ) ;  //3D Sphere
  
			
		
	
		
			
				
					surfaceArea  =  4 * Math . PI * Math . pow ( radiusTotal , 2 ) ;  //3D Sphere
  
			
		
	
		
			
				
					heatConvection  =  12 ;  // W/m2 K Some Reasonable estimate for natural Convection. Change as needed. 5-25
  
			
		
	
		
			
				
					thermalConduct  =  0.412  // W/m K
  
			
		
	
		
			
				
					cp  =  2810  // J/kg K
  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					mass  =  density  *  volume ;  
			
		
	
		
			
				
					
 
			
		
	
	
		
			
				
					
						
						
						
							
								 
						
					 
				
				@ -77,9 +79,14 @@ Qdot = -1*heatConvection*surfaceArea*(tempAtTime-tempInfini) //Heat Transfer Rat
				@@ -77,9 +79,14 @@ Qdot = -1*heatConvection*surfaceArea*(tempAtTime-tempInfini) //Heat Transfer Rat
					 
			
		
	
		
			
				
					console . log ( "The Heat Flux is "  +  Qdot  )  
			
		
	
		
			
				
					}  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  advancedLumpedCapacitanceMethod ( )  {  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					}  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  transientSphereOneTerm  ( rPosition , rTotal , tempInitial , tempInfini , t )  {  
			
		
	
		
			
				
					heatConvection  =  12 ;  // W/m2 K Some Reasonable estimate for natural Convection. Change as needed. 5-25
  
			
		
	
		
			
				
					thermalConduct  =  0.412  // W/m K
  
			
		
	
		
			
				
					alpha  =  thermalConduct / ( density * cp )  
			
		
	
		
			
				
					console . log ( "Alpha is "  +  alpha )  
			
		
	
		
			
				
					
 
			
		
	
	
		
			
				
					
						
							
								 
						
						
							
								 
						
						
					 
				
				@ -129,7 +136,7 @@ console.log("The Temperature At radius " + rPosition +" m and time " + t + "  se
				@@ -129,7 +136,7 @@ console.log("The Temperature At radius " + rPosition +" m and time " + t + "  se
					 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  findAllRoots  ( Biot )  {  
			
		
	
		
			
				
					limit  =  11  ;  //Terms to Compute too
  
			
		
	
		
			
				
					limit  =  150  ;  //Terms to Compute too
  
			
		
	
		
			
				
					storage  =  [ ] ;  
			
		
	
		
			
				
						for  ( var  k = 0 ;  k <= limit ;  k ++ )  {   
			
		
	
		
			
				
							minK  =  ( k + 0.5 ) * Math . PI ;   
			
		
	
	
		
			
				
					
						
						
						
							
								 
						
					 
				
				@ -139,14 +146,14 @@ storage = [];
				@@ -139,14 +146,14 @@ storage = [];
					 
			
		
	
		
			
				
							storage . push ( answer ) ;   
			
		
	
		
			
				
							}   
			
		
	
		
			
				
						}   
			
		
	
		
			
				
					console . log ( storage )  
			
		
	
		
			
				
					//console.log(storage)
  
			
		
	
		
			
				
					return ( storage )  
			
		
	
		
			
				
					}  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  bisectionMethod ( min , max , Biot )  {  
			
		
	
		
			
				
					errorTolerance  =  ( 1 / Math . pow ( 10 , 8 ) )  
			
		
	
		
			
				
					result  =  100 // some large value to ensure the calculation goes through.
  
			
		
	
		
			
				
					errorTolerance  =  ( 1 / Math . pow ( 10 , 9 ) )  
			
		
	
		
			
				
					result  =  Infinity // some large value to ensure the calculation goes through.
  
			
		
	
		
			
				
					negativeTest  = lambdaFormula ( min ,  Biot ) * lambdaFormula ( max ,  Biot )  
			
		
	
		
			
				
					if  ( negativeTest  <= 0  )  {  
			
		
	
		
			
				
						while  ( Math . abs ( result )  >  errorTolerance )  { 	
  
			
		
	
	
		
			
				
					
						
							
								 
						
						
							
								 
						
						
					 
				
				@ -178,12 +185,9 @@ return(result)
				@@ -178,12 +185,9 @@ return(result)
					 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					function  transientSphereSeries  ( rPosition , rTotal , tempInitial , tempInfini , t )  {  
			
		
	
		
			
				
					heatConvection  =  6000 ;  // W/m2 K Some Reasonable estimate for natural Convection. Change as needed. 5-25
  
			
		
	
		
			
				
					thermalConduct  =  20  // W/m K
  
			
		
	
		
			
				
					//alpha = thermalConduct/(density*cp)
  
			
		
	
		
			
				
					alpha  =  6.66  *  ( 1 / Math . pow ( 10 , 6 ) )  
			
		
	
		
			
				
					console . log ( "Alpha is "  +  alpha )  
			
		
	
		
			
				
					sum = 0 ;  
			
		
	
		
			
				
					alpha  =  thermalConduct / ( density * cp )  
			
		
	
		
			
				
					console . log ( "Alpha is "  +  alpha )  
			
		
	
		
			
				
					
 
			
		
	
		
			
				
					Fourier  =  ( alpha * t ) / Math . pow ( rTotal , 2 )  
			
		
	
		
			
				
					console . log ( "Fourier is "  +   Fourier )  
			
		
	
	
		
			
				
					
						
						
						
							
								 
						
					 
				
				@ -200,5 +204,7 @@ lambdaTerms = findAllRoots(biotNum)
				@@ -200,5 +204,7 @@ lambdaTerms = findAllRoots(biotNum)
					 
			
		
	
		
			
				
							sum  =  frontCoefficientPortion * exponentialPortion * sinPortion  +  sum   
			
		
	
		
			
				
					}  
			
		
	
		
			
				
					tempAtTimeAndRadius = ( sum * ( tempInitial - tempInfini ) ) + tempInfini  
			
		
	
		
			
				
					return ( tempAtTimeAndRadius )  
			
		
	
		
			
				
					console . log ( "The Temperature at radius "  +  rPosition  +  " m and time "  +  t  +  "  seconds is "  +  tempAtTimeAndRadius  +  " C or "  +  celsiusToFarenheit ( tempAtTimeAndRadius )  +  " F" ) ;  
			
		
	
		
			
				
					}